field data recording instrumentation and services
Celebrating 20 Years of Success in Field Data Collection!
2006 ESRI Business Partner of the Year!

Advanced   |   Sitemap
We have special pricing for academic and Federal organizations on many of the products we carry. Click here to get a quote.
 
juniper archer fild pc windows mobile 5.0 Archer Field PC
The Archer is your reliable tool for in-the-field information management. Now with Bluetooth!
 
All Topo Maps
Aurical Calibration Solutions
DataLink GIS
DataPlus
DataSight
GPS Photo Link & Ricoh Camera
Hydrolab Support
HydroPlus
In-Situ
ISCO Water Samplers/Flow Meters
Juniper Field Computers
FormsPlus
Trimble GPS
LaserTech Range Finders
LaserCraft Range Finders
Screen Protectors
Most Viewed
 
Academic / Federal
Trimble
ESRI
InSitu
ISCO
Everything Else
 
HydroPlus CE 4.xx
HydroPlus CE 2.07
FormsPlus
DataSight Lite 2.6
DataSight 2.7 Flash Demo
DataPlus MDB Converter
DataPlus Pro - New Users
DataPlus Patch - DOS prior v2.0
DataPlus Patch - v2.0 or later
DataLink GIS
 
Your Account
Contact Us
Seminars
Testimonials
Clearance Items
Used Demonstration Equipment
Classifieds
Last 20 added
Last 20 purchased
Best Sellers
HydroPlus CE CD and Printed User Manual >>
store.elecdata.com >> >> Hydroplus >> HydroPlus CE Software (Single Copy) with Hardware Purchase
HydroPlus CE Software (Single Copy) with Hardware Purchase
ProductID Category Price Buy It
HYD-210
Ask Question
Hydroplus $495.00
Quantity:

HydroPlus® CE software integrates a Windows® CE devices, a multiparameter probe, and a GPS receiver for collecting data in the field. Record both water quality parameters and GPS location with the click of button.

Features Include:

  • Interface hand held to In-Situ 9000/9500, YSI 6 Series, or Hydrolab 4a/5 Series Multiprobes
  • Direct communication with multiprobe for configuration, calibration, and data retrieval.
  • Optional GPS feature for position tagging water quality data and navigating to sampling locations.
  • Continual readout of position and water quality data.
  • Log position and water quality data with a click of a button.
  • The Timed Log feature allows data to be recorded at a preset interval.
  • Set up Location/Site information complete with GPS coordinates.
  • Dynamically resizes fonts to keep font size as large as possible, based on number of parameters selected and whether GPS is used.
  • Display up to 30 parameters on screen at a time.
  • Shows data in multiple units of measurement.
  • Grab Sample, User Notes and Field Sample Notes accommodated.
  • Color indication of whether a parameter is stable or not. Stabilization parameters are user definable.
  • Graph real-time data or historical data. Display up to three parameters on the display at a time.

    For In-Situ Probes:

  • User can save View and Logging setups on a per-probe basis. Saves time by not having to redefine settings each time.
  • Calibration reports are automatically generated with each calibration.
  • User can record calibration notes specific to probe, calibration type, calibration standard information, etc.
  • Pre-calibration and post-calibration readings are stored in calibration report.
  • User has choice of waiting for “Nominal” or “Stable” status while calibrating. User can specify how many readings are required for either classification.

    HydroPlus Host PC Software

  • Overlays Microsoft ActiveSync software for a user friendly interface for file transfers.
  • Converts data to ASCII text, .csv, .mdb, or .dbf formats. Flat-file conversion for Excel. Use data with ArcGIS.
  • Automates transfer and conversion processes. Simply plug the cable in and HydroPlus Host takes over from there.

    HydroPlus Table Editor PC Software

  • Edit .dbf tables that contain location & waypoint information.
  • Edit HydroPlus header or data log files.
      Compatible Systems:

      Desktop PC

    • Processor: 486 or higher
    • Operating System: Microsoft Windows 95, 98, Me, NT, 2000, or XP
    • RAM: 32 MB or Greater
    • Communication Port: USB cradle, IR port, or RS232 serial port with Microsoft ActiveSync connection

      Windows CE Device

    • Processor: Intel StrongARM compatible,
    • Operating System: Microsoft Windows CE CE.net 4.x, Windows Mobile 2003, 2003 Second Edition or Windows Mobile 5. (Older HydroPlus version available for CE 3.x & PocketPC 2002.)
    • Memory: 16 MB RAM (32 or greater recommended)
    • Desktop Software: Latest version of Microsoft ActiveSync recommended; v4.x required for Windows Mobile 5

      These Windows CE devices have been tested with HydroPlus CE:

    • In-Situ Rugged Reader
    • TDS/Trimble Ranger and Recon
    • Trimble GeoExplorer CE
    • Juniper Systems Allegro and Archer.

      Tested Multiprobes
      HydroPlus CE has been tested with the following multiprobes.

    • In-Situ MP-TROLL 9500, 9000 and miniTROLL probes
    • Hydrolab Series 4a/5 MiniSonde® or DataSonde® in ANSI mode.
    • YSI 6 Series
    • Either internal battery option or external battery pack is required.

      GPS Receivers
      Compatible GPS receivers that support any of the following GPS protocols:

    • NMEA (National Maritime Electronics Association) 0183
    • TSIP (Trimble’s binary protocol)

      If your system isn't listed, we'll test compatibility before you purchase.

      HydroPlus® CE Data Sheet

      Using HydroPlus® CE Data with ArcGIS 9.x

      HydroPlus CE - Demonstration Software Download.

      In-Situ MP-TROLL Water Quality Probe

      GPS Rugged Reader Bundles plus Other Application Software for Water Resource Applications

      DataSight - Data Management, Graphing and Analysis Software

      Trimble Mapping Receivers

      ESRI ArcPad Software


    • Search Our Inventory | Quotes | Testimonials | Contact Us | Sitemap
      Phone: (208) 324 - 8006   |   Fax: (208) 324 - 8015

      © Electronic Data Solutions 1998 - 2008